(A) Minimum lot size is dependent upon the size of the septic system. The lot must be large enough to accommodate the water system, and both the septic system and the repair area. The septic system must be 100 feet from a well used as the drinking water source for park residents. If a community or public water system is utilized, the water supply lines must be ten feet from all parts of the septic system. All square-foot requirements are subject to the approval of the County Environmental Health Department.
(B) Each manufactured home space shall be located on ground not susceptible to flooding and graded so as to prevent any water from ponding or accumulating on the premises.
(C) Each manufactured home space shall be clearly defined by means of concrete or iron pipe markers placed at all corners.
(D) There shall be at least 20 feet clearance between manufactured homes including manufactured homes parked end to end. No manufactured home shall be located closer than 20 feet to any building within the park, 15 feet from any property line, and at least 20 feet from the edge of the right-of-way of any interior street and 30 feet from the edge of the right-of-way of any publicly maintained street or road.
(E) The manufactured home shall be provided with anchors and tie downs as required by the manufacturers specifications of the State Department of Insurance. Each manufactured homeowner shall be responsible for securing his or her individual manufactured home to anchors.
(Ord. passed 10-2-2006)