§ 150.03 AS-BUILT DRAWINGS.
   Any individual appearing for himself/herself or any entity before the Town of Bargersville shall comply with the following requirements for the acceptance of “as-built” drawings (plans) not heretofore found to be exempt from these requirements by the Board:
   (A)   General requirements. Plans are to contain a certification statement that the improvements have been installed in reasonable compliance with the original design plans with respect to horizontal and vertical locations and grades and any deviations of locations, grade or material used are shown in these “as-built” drawings (plans). Said certification is to be sealed and signed by a professional licensed engineer or land surveyor in the State of Indiana.
   (B)   Specific requirements; grading or development plan(s); grades.
      (1)   Major drainage swales and percents of slope: at lot corner and grade breaks;
      (2)   Pad grades;
      (3)   Street grades;
         (a)   Centerline and curb if street is bituminous pavement with concrete curb.
         (b)   Centerline only if streets are concrete and placed with electronic control (maximum 50 feet spacing).
         (c)   All sag and crest points.
      (4)   Paved swales if any, at 50 feet intervals;
      (5)   Lake or pond if applicable: top bank, normal pool, safety ledge, bottom and spillway;
      (6)   Locations of sidewalk ramps.
   (B)   Plan and profiles.
      (1)   Sanitary sewers.
         (a)   Invert elevations and percents of slope;
         (b)   Top of casting elevations;
         (c)   Lateral locations based on distances along main from manholes;
         (d)   Locations of each manhole or structure (to make sure they are sufficiently within designated easements to permit future excavation to system if needed);
         (e)   Designate any material change from design plans; where plans show any alternates, indicate alternate actually used.
         (f)   Lift station and forcemain inverts, locations, pump data, etc.
      (2)   Storm sewers.
         (a)   Invert elevations and percents of slope;
         (b)   Top of casting elevations;
         (c)   Location of pipe and structures (to make sure they are within designated easements);
         (d)   Designate any material change from design plans; where plans show alternates, indicate alternate actually used.
      (3)   Streets.
         (a)   Grades;
         (b)   All low and high points;
         (c)   All percents of slope;
         (d)   Any deviation of alignment;
         (e)   Grades and dimensions on accel and decel lanes if applicable.
      (4)   Water.
         (a)   Location of main, valves, hydrants and fittings relative to the street curb line;
         (b)   Lengths of segments between fittings and transition size and material;
         (c)   Verification materials; and
         (d)   Identify any deviations in grade from standard depth.