§ 153.30 SPACE, USE AND LOCATION STANDARDS.
   (A)   Room sizes.
      (1)   Every dwelling unit shall contain at least the minimum room size in each habitable room as required by the Residential Building Code. (Floor area shall be calculated on the basis of habitable room area. However, closet area and wall area within the dwelling may count for not more than 10% of the required habitable floor area. The floor area of any part of any room where the ceiling height is less than four and one-half feet shall not be considered as a part of the floor area in computing the total area of the room to determine maximum permissible occupancy.)
      (2)   Every dwelling unit shall contain at least 150 square feet of habitable floor area for the first occupant, at least 100 square feet of additional habitable area for each of the next three occupants, and at least 75 square feet of additional habitable floor area for each additional occupant. In every dwelling unit and in every rooming unit, every room occupied for sleeping purposes by one occupant shall contain at least 70 square feet of floor area, and every room occupied for sleeping purposes by more than one occupant shall contain at least 50 square feet of floor area for each occupant 12 years of age and over, and at least 35 square feet of floor area for each occupant under 12 years of age.
   (B)   Ceiling height. At least one-half of the floor area of every habitable room shall have a ceiling height of not less than seven feet and six inches.
   (C)   Cellar. No cellar shall be used for living purposes unless:
      (1)   The floor and walls are substantially water-tight;
      (2)   The total window area, total openable window area and ceiling height are equal to those required for a habitable room; and
      (3)   The required minimum window area of every habitable room is entirely above the grade adjoining such window area, except where the windows face a stairwell, window well or access way.
(Ord. 05-6, passed 4-12-2005) Penalty, see § 10.99