§ 52.70 SAMPLING AND ANALYTICAL REQUIREMENTS.
   (A)   All pollutant analyses, including sampling techniques, to be submitted as part of a wastewater discharge permit application or report shall be performed in accordance with the techniques prescribed in 40 C.F.R. Part 136, unless otherwise specified in an applicable categorical pretreatment standard. If 40 C.F.R. Part 136 does not contain sampling or analytical techniques for the pollutant in question, sampling and analyses must be performed in accordance with procedures approved by EPA.
   (B)   Except as indicated in divisions (C) and (D) below, the user must collect wastewater samples using 24-hour flow-proportional composite sampling techniques, unless time-proportional composite sampling or grab sampling is authorized by the superintendent. Where time-proportional composite sampling or grab sampling is authorized by the village, the samples must be representative of the discharge. Using protocols (including appropriate preservation) specified in 40 C.F.R. Part 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited prior to the analysis as follows: for cyanide, total phenols, and sulfides the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease, the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the village, as appropriate. In addition, grab samples may be required to show compliance with instantaneous limits.
   (C)   Samples for oil and grease, temperature, pH, cyanide, phenols, sulfides, and volatile organic compounds must be obtained using grab collection techniques.
   (D)   For sampling required in support of baseline monitoring and 90-day compliance reports required in § 52.68 (40 C.F.R. § 403.12(b) and (d)), a minimum of four grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the Superintendent may authorize a lower minimum. For the reports required by § 52.68(B), periodic compliance reports (40 C.F.R. §§ 403.12(e) and 403.12(h)), the industrial user is required to collect the number of grab samples necessary to assess and assure compliance by with applicable pretreatment standards and requirements.
(Ord. 05-54, Art. V, § 10, passed 12-19-2005; Am. Ord. 10-56, Art. V, § 10, passed 10-11-2010) Penalty, see § 52.99