§ 153.61 SERVICE BUILDINGS.
   (A)   Each recreational vehicle park shall be provided with at least one service building adequately equipped with flush-type toilet fixtures and other sanitary facilities, as required in this subchapter. No service building shall contain less than one toilet for females, one toilet for males, one lavatory and shower for each sex, and one laundry tray. All sanitary facilities required by this subchapter shall be located in a service building.
   (B)   Each park accommodating recreational vehicles shall provide the following.
      (1)   Toilet facilities for males shall consist of not less than two flush toilets and one urinal for the first ten recreational vehicles or fraction thereof and, for recreational vehicles in excess of ten, not less than one additional flush toilet and one additional urinal for every ten additional recreational vehicles or fractional number thereof.
      (2)   Toilet facilities for females shall consist of not less than two flush toilets for the first six recreational vehicle spaces or any less number thereof and, for recreational vehicle spaces in excess of six, not less than one additional flush toilet for every ten additional recreational vehicle spaces in excess of six or fractional number thereof.
      (3)   Each sex shall be provided with not less than two lavatories and two showers or bathtubs with individual dressing accommodations for the first ten recreational vehicle spaces or any less number thereof and, for recreational vehicle spaces in excess of ten, not less than one additional lavatory and one additional shower or bathtub with individual dressing accommodations for every ten additional recreational vehicle spaces or fractional number thereof.
      (4)   Each toilet for females and each shower or bathtub with individual dressing accommodations for females shall be in a private compartment or stall.
      (5)   The toilet and other sanitation facilities for males and females shall either be separate buildings or shall be separated, if in the same building, by a soundproof wall.
      (6)   There shall be provided in a separate compartment or stall not less than one flush toilet bowl, receptacle for emptying bed pans and other containers of human excreta, or a slop sink with at least a three-inch trap and an adequate supply of hot running water for cleansing such bed pans or containers.
   (C)   Recreational vehicle spaces shall not be less than 200 feet from a private building.
   (D)   Service buildings shall:
      (1)   Be located 25 feet or more from any recreational vehicle space;
      (2)   Be of permanent construction and be adequately lighted;
      (3)   Be of moisture-resistant material to permit frequent washing and cleansing;
      (4)   Have adequate heating facilities to maintain a temperature of 70°F during cold weather and to supply adequate hot water during time of peak demands; and
      (5)   Have all rooms well ventilated with all openings effectively screened.
   (E)   Laundry facilities shall be provided in the ratio of one laundry unit to every 30 recreational vehicle spaces and shall be in a separate, soundproof room of a service building or in a separate building. A laundry shall consist of not less than one clothes-drying machine and one clothes- washing machine.
   (F)   All service buildings and the grounds of the park shall be maintained in a clean condition and kept free of any condition that will menace the health of any occupant or the public or constitute a menace.
(Prior Code, § 12-36)