(A) General. All sketch plats submitted to the Plan Commission, prepared in pen or pencil, shall be drawn to a convenient “engineer’s” scale of not more than 100 feet to an inch and shall show all information described in this section.
(B) Name.
(1) Name of subdivision if property is within an existing subdivision.
(2) Proposed name if not within a previously platted subdivision.
(C) Ownership.
(1) Name and address, including telephone number, of legal owner or agent of property involved giving grantor, grantee, date, and land records reference.
(2) Citation of any existing legal rights-of- way or easements affecting the property.
(3) Existing covenants on the property, if any.
(4) Name and address, including telephone number, of the professional engineers and surveyors responsible for subdivision design, for the design of public improvements, and for surveys.
(D) Description. Location of property by lot, section, township, range and county, and it shall include a graphic scale, north arrow and date.
(E) Features.
(1) Location of property lines, existing easements, burial grounds, railroad rights-of-way, watercourses, and existing wooded areas or trees eight inches or more in diameter, measured four feet above ground level; location, width, and names of all existing or platted streets or other public ways within or immediately adjacent to the tract.
(2) Location, sizes, elevations, and slopes of existing sewers, water mains, culverts, and other underground structures within the tract and immediately adjacent thereto; existing permanent buildings and utility poles on or immediately adjacent to the tract, and utility rights-of-way.
(3) Approximate topography at the same scale as the sketch plat.
(4) The approximate location and widths of proposed streets.
(5) Preliminary proposals for connection with existing water supply and sanitary sewer systems, or alternative means of providing water supply and sanitary waste disposal and treatment; preliminary provisions for collecting and discharging surface water drainage.
(6) The approximate location, dimensions, and areas of all proposed or existing lots.
(7) The approximate location, dimensions, and area of all parcels of land proposed to be set aside for park or playground use or other public use, or for the use of property owners in the proposed subdivision.
(8) The location of temporary stakes to enable the Town Engineer to find and appraise features of the sketch plat in the field, if needed.
(9) Whenever the sketch plat covers only a part of an applicant’s contiguous holdings, the applicant shall submit, at the scale of no more than 200 feet to the inch, a sketch in pen or pencil of the proposed subdivision area, together with its proposed street system, and an indication of the probable future street and drainage system of the remaining portion of the tract.
(10) A vicinity map showing streets and other general development of the surrounding area. The sketch plat shall show all school and improvement district lines with the districts (or zones) properly designated.
(Ord. - -, passed - -80)