A. Sidewalks shall be required on public streets as determined by the reviewing authority. Sidewalks shall be constructed of concrete, with a minimum width of six (6) feet, exclusive of the curb. Any sidewalk constructed within two and one-half (2-1/2) feet from face of curb shall join to back of curb. Considerations in design are to be given for handicapped persons so that a clear path of travel of at least four (4) feet is provided, in accordance with current State and Federal Americans with Disabilities Act requirements.
B. Additional sidewalks on site may be required through the design review process, the sidewalk system shall provide for a safe, continuous pedestrian circulation and access system to all parts of the development. Pedestrian access shall be provided from public streets and parking lots to building entries, and walkways provided on-site shall connect with those off-site.
C. Pedestrian Circulation Standards shall conform with the Engineering Department Standards, Drawings and Specifications approved by the City Engineer.