The standards for each zone are set forth in the table below:
NR | Natural Reserve |
RA | Rural Area |
SN | Suburban Neighborhood |
MP | Mobile/Manufactured Park |
MU | Mixed Urban |
UC | Urban Corridor |
TD | Transit Development |
CP/EI | Commerce Park and Employment/Industry |
TABLE OF ZONE STANDARDS | ||||||||
Standard | NR | RA | SN | MP | MU | UC | TD | CP/EI |
TABLE OF ZONE STANDARDS | ||||||||
Standard | NR | RA | SN | MP | MU | UC | TD | CP/EI |
LOT OCCUPATION | ||||||||
Lot Area (sq. ft.) | per site plan | 43,560 | 5,000 | 2,000 | 4,000 | 2,000 | 1,000 | 2,000 |
Lot Width (minimum) | per site plan | 120 ft. | 45 ft. | 40 ft. | 40 ft. | 20 ft. | 20 ft. | 50 ft. |
Lot Cover (maximum) | per site plan | 25% | 55% | 80% | 90% | 90% | 90% | 90% |
MINIMUM SETBACKS - PRINCIPAL BUILDING | ||||||||
Front (minimum) | per site plan | 30 ft. | 20 ft. | 5 ft. | 10 ft. | 5 ft. * | 5 ft. * | 20 ft. |
Side St. (minimum) | per site plan | 20 ft. | 10 ft. | 5 ft. | 10 ft. | 5 ft. * | 5 ft.* | 10 ft. |
Int. Side (minimum) | per site plan | 20 ft. | 5 ft. | 5 ft. * | 5 ft. * | 5 ft. * | 5 ft. * | 5 ft. * |
Rear (minimum) | per site plan | 30 ft. | 20 ft.**** | 5 ft. | 10 ft. | 5 ft. * | 5 ft. * | 5 ft. * |
MINIMUM SETBACKS-ACCESSORY BUILDING, STRUCTURES, AND USES | ||||||||
MAXIMUM BUILDING HEIGHT*** | ||||||||
Principal (height/stories) | per site plan** | 30 ft./2 | 30 ft./2 | 30 ft./2** | 30 ft./2** | 40 ft./3** | 70 ft./5** | 66 ft.** |
* No setback is required if structure is fire resistant per International Building Code and Fire Code (IBC and IFC).
** Principal buildings may exceed the maximum building height or stories with conditional use permit approval.
*** Any building above 30 feet in height shall be subject to additional fire protection precautions per IBC and IFC.
**** The minimum rear setback for developments over 30 acres shall be 15 feet.
(Res. R22-05-08, passed 5-3-2022; Ord. O22-05-02, passed 5-3-2022)